minor updates.

This commit is contained in:
Mahasri Kalavala 2019-05-14 19:32:32 -04:00
parent cb50a7229d
commit 1d01811938
6 changed files with 99 additions and 45 deletions

View File

@ -402,7 +402,7 @@ automation:
action: action:
- service: script.notify_me - service: script.notify_me
data_template: data_template:
message: "{{ trigger.to_state.attributes.friendly_name }}'s phone battery is less than: {{ trigger.to_state.attributes.battery }}%." message: "{{ trigger.to_state.attributes.friendly_name | title }}'s phone battery is less than: {{ trigger.to_state.attributes.battery }}%."
- service: script.voice_notify - service: script.voice_notify
data_template: data_template:
message: "{{ trigger.to_state.attributes.friendly_name }}'s phone battery is less than: {{ trigger.to_state.attributes.battery }}%." message: "{{ trigger.to_state.attributes.friendly_name }}'s phone battery is less than: {{ trigger.to_state.attributes.battery }}%."

View File

@ -17,9 +17,6 @@ homeassistant:
customize: &customize customize: &customize
package: 'cameras' package: 'cameras'
hidden: &hidden
<<: *customize
hidden: true
# #
# The camera url format in secrets.yaml would look like this: # The camera url format in secrets.yaml would look like this:
@ -294,7 +291,18 @@ automation:
- service: notify.notify_smtp - service: notify.notify_smtp
data_template: data_template:
title: 'Front door motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}' title: 'Front door motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}'
message: 'Motion detected at the front door on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.' message: >
{%- set e_id = "image_processing.tensorflow_frontdoor_camera" -%}
{%- if state_attr(e_id, 'summary') -%}
{%- set count = state_attr(e_id, 'summary') | count -%}
{%- for x in state_attr(e_id, 'summary') | list -%}
{%- if loop.first %}{% elif loop.last %}, and {% else %}, {% endif -%}
{{- state_attr(e_id, 'summary')[x]}} {{ x ~ 's' if state_attr(e_id, 'summary')[x] > 1 else x }}
{%- endfor -%}
{{ " detected in the front yard on " ~ now().strftime("%d %h %Y, at %I:%M:%S %p") ~ ". Please see the images below." }}
{% else %}
Motion detected in the front door on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.
{%- endif -%}
data: data:
images: images:
- "/home/homeassistant/.homeassistant/www/downloads/camera/frontdoor/frontdoor_latest.jpg" - "/home/homeassistant/.homeassistant/www/downloads/camera/frontdoor/frontdoor_latest.jpg"
@ -362,7 +370,18 @@ automation:
- service: notify.notify_smtp - service: notify.notify_smtp
data_template: data_template:
title: 'Driveway motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}' title: 'Driveway motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}'
message: 'Motion detected at the driveway on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.' message: >
{%- set e_id = "image_processing.tensorflow_driveway_camera" -%}
{%- if state_attr(e_id, 'summary') -%}
{%- set count = state_attr(e_id, 'summary') | count -%}
{%- for x in state_attr(e_id, 'summary') | list -%}
{%- if loop.first %}{% elif loop.last %}, and {% else %}, {% endif -%}
{{- state_attr(e_id, 'summary')[x]}} {{ x ~ 's' if state_attr(e_id, 'summary')[x] > 1 else x }}
{%- endfor -%}
{{ " detected in the driveway on " ~ now().strftime("%d %h %Y, at %I:%M:%S %p") ~ ". Please see the images below." }}
{% else %}
Motion detected at the driveway on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.
{%- endif -%}
data: data:
images: images:
- "/home/homeassistant/.homeassistant/www/downloads/camera/driveway/driveway_latest.jpg" - "/home/homeassistant/.homeassistant/www/downloads/camera/driveway/driveway_latest.jpg"
@ -439,7 +458,18 @@ automation:
- service: notify.notify_smtp - service: notify.notify_smtp
data_template: data_template:
title: 'Garage motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}' title: 'Garage motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}'
message: 'Motion detected in the garage on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.' message: >
{%- set e_id = "image_processing.tensorflow_garage_camera" -%}
{%- if state_attr(e_id, 'summary') -%}
{%- set count = state_attr(e_id, 'summary') | count -%}
{%- for x in state_attr(e_id, 'summary') | list -%}
{%- if loop.first %}{% elif loop.last %}, and {% else %}, {% endif -%}
{{- state_attr(e_id, 'summary')[x]}} {{ x ~ 's' if state_attr(e_id, 'summary')[x] > 1 else x }}
{%- endfor -%}
{{ " detected in the garage on " ~ now().strftime("%d %h %Y, at %I:%M:%S %p") ~ ". Please see the images below." }}
{% else %}
Motion detected in the garage on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.
{%- endif -%}
data: data:
images: images:
- "/home/homeassistant/.homeassistant/www/downloads/camera/garage/garage_latest.jpg" - "/home/homeassistant/.homeassistant/www/downloads/camera/garage/garage_latest.jpg"
@ -496,7 +526,18 @@ automation:
- service: notify.notify_smtp - service: notify.notify_smtp
data_template: data_template:
title: 'Backyard motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}' title: 'Backyard motion {{ now().strftime("%d %h %Y, %I:%M:%S %p") }}'
message: 'Motion detected in the backyard on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.' message: >
{%- set e_id = "image_processing.tensorflow_patio_camera" -%}
{%- if state_attr(e_id, 'summary') -%}
{%- set count = state_attr(e_id, 'summary') | count -%}
{%- for x in state_attr(e_id, 'summary') | list -%}
{%- if loop.first %}{% elif loop.last %}, and {% else %}, {% endif -%}
{{- state_attr(e_id, 'summary')[x]}} {{ x ~ 's' if state_attr(e_id, 'summary')[x] > 1 else x }}
{%- endfor -%}
{{ " detected in the backyard on " ~ now().strftime("%d %h %Y, at %I:%M:%S %p") ~ ". Please see the images below." }}
{% else %}
Motion detected in the backyard on {{ now().strftime("%d %h %Y, at %I:%M:%S %p") }}. Please see the images below.
{%- endif -%}
data: data:
images: images:
- "/home/homeassistant/.homeassistant/www/downloads/camera/patio/patio_latest.jpg" - "/home/homeassistant/.homeassistant/www/downloads/camera/patio/patio_latest.jpg"

View File

@ -180,6 +180,9 @@ automation:
- condition: state - condition: state
entity_id: input_boolean.light_automations entity_id: input_boolean.light_automations
state: 'on' state: 'on'
- condition: state
entity_id: input_boolean.movie_time
state: 'off'
action: action:
- service: switch.turn_on - service: switch.turn_on
data: data:

View File

@ -53,11 +53,11 @@ notify:
sender: !secret smtp_sender sender: !secret smtp_sender
recipient: !secret smtp_recipient recipient: !secret smtp_recipient
- name: notify_aws_sns # - name: notify_aws_sns
platform: aws_sns # platform: aws_sns
aws_access_key_id: !secret aws_access_key_id # aws_access_key_id: !secret aws_access_key_id
aws_secret_access_key: !secret aws_secret_access_key # aws_secret_access_key: !secret aws_secret_access_key
region_name: 'us-east-1' # region_name: 'us-east-1'
- name: file_notify - name: file_notify
platform: file platform: file

View File

@ -994,3 +994,12 @@
# data: # data:
# payload: 'stop' # payload: 'stop'
# topic: 'robotic_mower/control' # topic: 'robotic_mower/control'
# sensor:
# - platform: rest
# resource: https://pollenkontroll.no/api/pollen-count?country=no&location=126
# name: Pollen
# value_template: >-
# {% for city in value_json.cities if city.id == '126' %}
# {{ city.id }}
# {% endfor %}

View File

@ -34,10 +34,10 @@
</CommandClass> </CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true"> <CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="67.1" /> <Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="67.4" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" /> <Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
<Value type="decimal" genre="user" instance="1" index="4" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="46" /> <Value type="decimal" genre="user" instance="1" index="4" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="46" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="46" /> <Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="56" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" after_mark="true" innif="true"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" after_mark="true" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -168,7 +168,7 @@
</CommandClass> </CommandClass>
<CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="4" innif="true"> <CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="33" /> <Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="28" />
</CommandClass> </CommandClass>
<CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true"> <CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -208,7 +208,7 @@
</CommandClass> </CommandClass>
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true"> <CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" /> <Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="True" />
<SensorMap index="0" type="46" /> <SensorMap index="0" type="46" />
<SensorMap index="0" type="62" /> <SensorMap index="0" type="62" />
<SensorMap index="0" type="193" /> <SensorMap index="0" type="193" />
@ -216,9 +216,9 @@
</CommandClass> </CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true"> <CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="66.0" /> <Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="67.6" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="5" /> <Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="5" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="47" /> <Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="57" />
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" /> <Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" after_mark="true" innif="true"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" after_mark="true" innif="true">
@ -386,7 +386,7 @@
<CommandClasses> <CommandClasses>
<CommandClass id="32" name="COMMAND_CLASS_BASIC" version="1" request_flags="4" innif="true" setasreport="true"> <CommandClass id="32" name="COMMAND_CLASS_BASIC" version="1" request_flags="4" innif="true" setasreport="true">
<Instance index="1" /> <Instance index="1" />
<Value type="byte" genre="basic" instance="1" index="0" label="Basic" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="255" /> <Value type="byte" genre="basic" instance="1" index="0" label="Basic" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
</CommandClass> </CommandClass>
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true"> <CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -728,9 +728,9 @@
</CommandClass> </CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true"> <CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="71.0" /> <Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="72.1" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="19" /> <Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="4" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="48" /> <Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="56" />
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" /> <Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
@ -1006,11 +1006,11 @@
</CommandClass> </CommandClass>
<CommandClass id="50" name="COMMAND_CLASS_METER" version="3" request_flags="2" innif="true"> <CommandClass id="50" name="COMMAND_CLASS_METER" version="3" request_flags="2" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="0" label="Energy" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43.410" /> <Value type="decimal" genre="user" instance="1" index="0" label="Energy" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="44.076" />
<Value type="decimal" genre="user" instance="1" index="1" label="Previous Reading" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43.410" /> <Value type="decimal" genre="user" instance="1" index="1" label="Previous Reading" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="44.055" />
<Value type="int" genre="user" instance="1" index="2" label="Interval" units="seconds" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="-2147483648" max="2147483647" value="367" /> <Value type="int" genre="user" instance="1" index="2" label="Interval" units="seconds" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="-2147483648" max="2147483647" value="27671" />
<Value type="decimal" genre="user" instance="1" index="8" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" /> <Value type="decimal" genre="user" instance="1" index="8" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" />
<Value type="decimal" genre="user" instance="1" index="16" label="Voltage" units="V" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="123.735" /> <Value type="decimal" genre="user" instance="1" index="16" label="Voltage" units="V" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="121.939" />
<Value type="decimal" genre="user" instance="1" index="20" label="Current" units="A" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" /> <Value type="decimal" genre="user" instance="1" index="20" label="Current" units="A" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" />
<Value type="bool" genre="user" instance="1" index="32" label="Exporting" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" /> <Value type="bool" genre="user" instance="1" index="32" label="Exporting" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
<Value type="button" genre="system" instance="1" index="33" label="Reset" units="" read_only="false" write_only="true" verify_changes="false" poll_intensity="0" min="0" max="0" /> <Value type="button" genre="system" instance="1" index="33" label="Reset" units="" read_only="false" write_only="true" verify_changes="false" poll_intensity="0" min="0" max="0" />
@ -1190,8 +1190,8 @@
<Item label="Saturday" value="6" /> <Item label="Saturday" value="6" />
<Item label="Sunday" value="7" /> <Item label="Sunday" value="7" />
</Value> </Value>
<Value type="byte" genre="user" instance="1" index="1" label="Hour" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="11" /> <Value type="byte" genre="user" instance="1" index="1" label="Hour" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="12" />
<Value type="byte" genre="user" instance="1" index="2" label="Minute" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="57" /> <Value type="byte" genre="user" instance="1" index="2" label="Minute" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="38" />
</CommandClass> </CommandClass>
<CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true"> <CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -1703,18 +1703,18 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="25" name="Basement Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Session"> <Node id="25" name="Basement Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink"> <Manufacturer id="14a" name="Ecolink">
<Product type="4" id="2" name="Unknown: type=0004, id=0002" /> <Product type="4" id="2" name="Unknown: type=0004, id=0002" />
</Manufacturer> </Manufacturer>
<CommandClasses> <CommandClasses>
<CommandClass id="32" name="COMMAND_CLASS_BASIC" version="1" request_flags="4" innif="true"> <CommandClass id="32" name="COMMAND_CLASS_BASIC" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="byte" genre="basic" instance="1" index="0" label="Basic" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="255" /> <Value type="byte" genre="basic" instance="1" index="0" label="Basic" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
</CommandClass> </CommandClass>
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true"> <CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" /> <Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="True" />
<SensorMap index="0" type="255" /> <SensorMap index="0" type="255" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1">
@ -1734,7 +1734,7 @@
<Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="9" label="Access Control" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="23" /> <Value type="byte" genre="user" instance="1" index="9" label="Access Control" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="22" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="11" label="Power Management" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="11" label="Power Management" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
</CommandClass> </CommandClass>
@ -1809,7 +1809,7 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="27" name="Wallmote" location="" basic="4" generic="24" specific="1" roletype="4" devicetype="7172" nodetype="0" type="Basic Wall Controller" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Associations"> <Node id="27" name="Wallmote" location="" basic="4" generic="24" specific="1" roletype="4" devicetype="7172" nodetype="0" type="Basic Wall Controller" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="86" name="Aeotec"> <Manufacturer id="86" name="Aeotec">
<Product type="102" id="82" name="ZW130 WallMote Quad" /> <Product type="102" id="82" name="ZW130 WallMote Quad" />
</Manufacturer> </Manufacturer>
@ -2023,7 +2023,7 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="28" name="Audio Detector" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3073" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete"> <Node id="28" name="Audio Detector" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3073" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink"> <Manufacturer id="14a" name="Ecolink">
<Product type="5" id="f" name="FireFighter" /> <Product type="5" id="f" name="FireFighter" />
</Manufacturer> </Manufacturer>
@ -2038,7 +2038,7 @@
</CommandClass> </CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="7" innif="true"> <CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="7" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="68.90" /> <Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="69.62" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -2253,7 +2253,7 @@
</CommandClass> </CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" request_flags="1" innif="true"> <CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" request_flags="1" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="59.0" /> <Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="60.9" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="5" innif="true"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="5" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -2341,7 +2341,7 @@
</CommandClass> </CommandClass>
<CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="5" innif="true"> <CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="5" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="45" /> <Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="49" />
</CommandClass> </CommandClass>
<CommandClass id="132" name="COMMAND_CLASS_WAKE_UP" version="2" request_flags="1" innif="true"> <CommandClass id="132" name="COMMAND_CLASS_WAKE_UP" version="2" request_flags="1" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -2405,10 +2405,11 @@
</CommandClass> </CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true"> <CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" /> <Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="72.8" /> <Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="72.7" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" /> <Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="44" /> <Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="54" />
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" /> <Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
<Value type="decimal" genre="user" instance="1" index="37" label="Radon Concentration" units="bq/m3" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="60" />
</CommandClass> </CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true"> <CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -2579,7 +2580,7 @@
<Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" /> <Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="254" /> <Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
</CommandClass> </CommandClass>
<CommandClass id="114" name="COMMAND_CLASS_MANUFACTURER_SPECIFIC" version="1" request_flags="4" innif="true"> <CommandClass id="114" name="COMMAND_CLASS_MANUFACTURER_SPECIFIC" version="1" request_flags="4" innif="true">
<Instance index="1" /> <Instance index="1" />
@ -2665,7 +2666,7 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="38" name="" location="" basic="4" generic="7" specific="1" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="WakeUp"> <Node id="38" name="" location="" basic="4" generic="7" specific="1" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="NodeInfo">
<Manufacturer id="0" name=""> <Manufacturer id="0" name="">
<Product type="0" id="0" name="" /> <Product type="0" id="0" name="" />
</Manufacturer> </Manufacturer>
@ -2680,7 +2681,7 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="39" name="" location="" basic="4" generic="49" specific="1" type="Simple Meter" listening="true" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad"> <Node id="39" name="" location="" basic="4" generic="49" specific="1" type="Simple Meter" listening="true" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Manufacturer id="0" name=""> <Manufacturer id="0" name="">
<Product type="0" id="0" name="" /> <Product type="0" id="0" name="" />
</Manufacturer> </Manufacturer>
@ -2703,7 +2704,7 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="41" name="" location="" basic="4" generic="7" specific="1" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Probe"> <Node id="41" name="" location="" basic="4" generic="7" specific="1" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="WakeUp">
<Manufacturer id="0" name=""> <Manufacturer id="0" name="">
<Product type="0" id="0" name="" /> <Product type="0" id="0" name="" />
</Manufacturer> </Manufacturer>
@ -2718,7 +2719,7 @@
</CommandClass> </CommandClass>
</CommandClasses> </CommandClasses>
</Node> </Node>
<Node id="42" name="Front Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3078" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad"> <Node id="42" name="Front Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3078" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Associations">
<Manufacturer id="86" name="Aeotec"> <Manufacturer id="86" name="Aeotec">
<Product type="102" id="78" name="ZW120 Door Window Sensor Gen5" /> <Product type="102" id="78" name="ZW120 Door Window Sensor Gen5" />
</Manufacturer> </Manufacturer>