minor updates

This commit is contained in:
Mahasri Kalavala 2019-04-27 16:11:34 -04:00
parent 65d340e58e
commit 4080b58a16
2 changed files with 35 additions and 33 deletions

View File

@ -18,7 +18,8 @@
{%- macro tesla_status() -%}
{% if states("sensor.tesla_model_3_5yj3e1ea8jf010610_range_sensor") != "unknown" %}
{%- if (states('sensor.tesla_model_3_5yj3e1ea8jf010610_range_sensor') | int) | round(0) < 75 -%}
{%- if (states('sensor.tesla_model_3_5yj3e1ea8jf010610_range_sensor') | int) | round(0) < 75 and
(states('sensor.tesla_model_3_5yj3e1ea8jf010610_range_sensor') | int) | round(0) > 0 -%}
Attention!. Your Tesla car battery is at {{ states('sensor.tesla_model_3_5yj3e1ea8jf010610_battery_sensor') }} percent. and you can only drive about {{ (states('sensor.tesla_model_3_5yj3e1ea8jf010610_range_sensor') | int) | round(0) }} miles. Please charge your car if you want to go anywhere.
{%- endif -%}
{% endif %}
@ -148,7 +149,8 @@
{# Only notify pollen levels in spring #}
{%- macro pollen_levels() -%}
{% if states('sensor.season') | lower == "spring" %}
{% if states('sensor.pollen_level') | lower != "low" %}
{% if states('sensor.pollen_level') | lower != "low" and
states('sensor.pollen_level') | lower != "unknown" %}
Pollen level is {{ states('sensor.pollen_level') }}.
{% endif %}
{% endif %}

View File

@ -35,7 +35,7 @@
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="67.1" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="9" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
<Value type="decimal" genre="user" instance="1" index="4" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="46" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="46" />
</CommandClass>
@ -216,8 +216,8 @@
</CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="65.8" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="6" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="66.0" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="5" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="47" />
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
</CommandClass>
@ -379,7 +379,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="4" name="Two Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Node id="4" name="Two Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink">
<Product type="4" id="3" name="Garage Door Tilt Sensor" />
</Manufacturer>
@ -490,7 +490,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="5" name="Single Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Node id="5" name="Single Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink">
<Product type="4" id="3" name="Garage Door Tilt Sensor" />
</Manufacturer>
@ -601,7 +601,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="6" name="Back Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Node id="6" name="Back Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink">
<Product type="4" id="2" name="Door Sensor" />
</Manufacturer>
@ -728,9 +728,9 @@
</CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="71.1" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="27" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="47" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="71.0" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="19" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="48" />
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
</CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
@ -1006,11 +1006,11 @@
</CommandClass>
<CommandClass id="50" name="COMMAND_CLASS_METER" version="3" request_flags="2" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="0" label="Energy" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43.085" />
<Value type="decimal" genre="user" instance="1" index="1" label="Previous Reading" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43.026" />
<Value type="int" genre="user" instance="1" index="2" label="Interval" units="seconds" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="-2147483648" max="2147483647" value="65535" />
<Value type="decimal" genre="user" instance="1" index="0" label="Energy" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43.410" />
<Value type="decimal" genre="user" instance="1" index="1" label="Previous Reading" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43.410" />
<Value type="int" genre="user" instance="1" index="2" label="Interval" units="seconds" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="-2147483648" max="2147483647" value="367" />
<Value type="decimal" genre="user" instance="1" index="8" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" />
<Value type="decimal" genre="user" instance="1" index="16" label="Voltage" units="V" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="122.711" />
<Value type="decimal" genre="user" instance="1" index="16" label="Voltage" units="V" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="123.735" />
<Value type="decimal" genre="user" instance="1" index="20" label="Current" units="A" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" />
<Value type="bool" genre="user" instance="1" index="32" label="Exporting" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
<Value type="button" genre="system" instance="1" index="33" label="Reset" units="" read_only="false" write_only="true" verify_changes="false" poll_intensity="0" min="0" max="0" />
@ -1181,7 +1181,7 @@
</CommandClass>
<CommandClass id="129" name="COMMAND_CLASS_CLOCK" version="1" request_flags="4" innif="true">
<Instance index="1" />
<Value type="list" genre="user" instance="1" index="0" label="Day" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" vindex="4" size="1">
<Value type="list" genre="user" instance="1" index="0" label="Day" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" vindex="2" size="1">
<Item label="Monday" value="1" />
<Item label="Tuesday" value="2" />
<Item label="Wednesday" value="3" />
@ -1190,8 +1190,8 @@
<Item label="Saturday" value="6" />
<Item label="Sunday" value="7" />
</Value>
<Value type="byte" genre="user" instance="1" index="1" label="Hour" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="15" />
<Value type="byte" genre="user" instance="1" index="2" label="Minute" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="20" />
<Value type="byte" genre="user" instance="1" index="1" label="Hour" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="11" />
<Value type="byte" genre="user" instance="1" index="2" label="Minute" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="57" />
</CommandClass>
<CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true">
<Instance index="1" />
@ -1328,7 +1328,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="17" name="Stairs Motion Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Node id="17" name="Stairs Motion Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink">
<Product type="4" id="1" name="Motion Detector" />
</Manufacturer>
@ -1339,7 +1339,7 @@
</CommandClass>
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
<Instance index="1" />
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="True" />
<SensorMap index="0" type="255" />
</CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1">
@ -1369,7 +1369,7 @@
<Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="8" />
<Value type="byte" genre="user" instance="1" index="11" label="Power Management" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
</CommandClass>
<CommandClass id="114" name="COMMAND_CLASS_MANUFACTURER_SPECIFIC" version="1" request_flags="4" innif="true">
@ -1703,7 +1703,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="25" name="Basement Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Node id="25" name="Basement Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Session">
<Manufacturer id="14a" name="Ecolink">
<Product type="4" id="2" name="Unknown: type=0004, id=0002" />
</Manufacturer>
@ -1809,7 +1809,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="27" name="Wallmote" location="" basic="4" generic="24" specific="1" roletype="4" devicetype="7172" nodetype="0" type="Basic Wall Controller" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Node id="27" name="Wallmote" location="" basic="4" generic="24" specific="1" roletype="4" devicetype="7172" nodetype="0" type="Basic Wall Controller" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Associations">
<Manufacturer id="86" name="Aeotec">
<Product type="102" id="82" name="ZW130 WallMote Quad" />
</Manufacturer>
@ -2038,7 +2038,7 @@
</CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="7" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="71.78" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="68.90" />
</CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
<Instance index="1" />
@ -2132,7 +2132,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="29" name="Garage Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Node id="29" name="Garage Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Manufacturer id="14a" name="Ecolink">
<Product type="4" id="2" name="Unknown: type=0004, id=0002" />
</Manufacturer>
@ -2245,7 +2245,7 @@
<CommandClasses>
<CommandClass id="32" name="COMMAND_CLASS_BASIC" version="1" request_flags="5">
<Instance index="1" />
<Value type="byte" genre="basic" instance="1" index="0" label="Basic" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="255" />
<Value type="byte" genre="basic" instance="1" index="0" label="Basic" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
</CommandClass>
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1">
<Instance index="1" />
@ -2253,7 +2253,7 @@
</CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" request_flags="1" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="57.7" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="59.0" />
</CommandClass>
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="5" innif="true">
<Instance index="1" />
@ -2286,7 +2286,7 @@
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="7" label="Heat" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="254" />
<Value type="byte" genre="user" instance="1" index="8" label="Flood" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="8" label="Flood" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="254" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="254" />
<Value type="byte" genre="user" instance="2" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="2" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
@ -2341,7 +2341,7 @@
</CommandClass>
<CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="5" innif="true">
<Instance index="1" />
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="55" />
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="45" />
</CommandClass>
<CommandClass id="132" name="COMMAND_CLASS_WAKE_UP" version="2" request_flags="1" innif="true">
<Instance index="1" />
@ -2405,7 +2405,7 @@
</CommandClass>
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
<Instance index="1" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="72.9" />
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="72.8" />
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="44" />
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
@ -2579,7 +2579,7 @@
<Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="254" />
</CommandClass>
<CommandClass id="114" name="COMMAND_CLASS_MANUFACTURER_SPECIFIC" version="1" request_flags="4" innif="true">
<Instance index="1" />
@ -2652,7 +2652,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="36" name="" location="" basic="4" generic="33" specific="1" type="Routing Multilevel Sensor" listening="true" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
<Node id="36" name="" location="" basic="4" generic="33" specific="1" type="Routing Multilevel Sensor" listening="true" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
<Manufacturer id="0" name="">
<Product type="0" id="0" name="" />
</Manufacturer>
@ -2665,7 +2665,7 @@
</CommandClass>
</CommandClasses>
</Node>
<Node id="38" name="" location="" basic="4" generic="7" specific="1" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Probe">
<Node id="38" name="" location="" basic="4" generic="7" specific="1" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="WakeUp">
<Manufacturer id="0" name="">
<Product type="0" id="0" name="" />
</Manufacturer>