Add actionable Phyn restore notification
This commit is contained in:
@@ -5,13 +5,36 @@
|
||||
# -------------------------------------------------------------------
|
||||
# Phyn Plus Water Shutoff - Leak detection and auto shutoff
|
||||
# Related Issue: 1550
|
||||
# Push + Activity feed + Repairs issue while valve is closed.
|
||||
# Push action buttons + Activity feed + Repairs issue while valve is closed.
|
||||
# -------------------------------------------------------------------
|
||||
# Info: https://www.vcloudinfo.com/2020/05/phyn-plus-smart-water-shutoff-device.html
|
||||
# HACS: https://github.com/MizterB/homeassistant-phyn
|
||||
# Product: https://amzn.to/2Zy3sbJ
|
||||
######################################################################
|
||||
|
||||
script:
|
||||
phyn_send_actionable_leak_notification:
|
||||
alias: "Phyn Send Actionable Leak Notification"
|
||||
mode: parallel
|
||||
fields:
|
||||
source:
|
||||
description: "Caller context for trace/debug visibility."
|
||||
example: "initial"
|
||||
sequence:
|
||||
- service: script.notify_engine_two_button
|
||||
data:
|
||||
title: "Phyn Leak Detection"
|
||||
value1: "Phyn is sensing a leak and turned off the water. Please verify."
|
||||
who: "parents"
|
||||
group: "Phyn"
|
||||
title1: "Turn Water On"
|
||||
action1: "PHYN_WATER_ON"
|
||||
title2: "Snooze 30m"
|
||||
action2: "SNOOZE_PHYN_NOTIFICATION"
|
||||
icon1: "sfsymbols:arrow.up.circle"
|
||||
icon2: "sfsymbols:clock"
|
||||
level: "critical"
|
||||
|
||||
automation:
|
||||
- alias: 'Phyn ShutOff Notification'
|
||||
id: 78bbd270-ee1e-4b3d-80fd-44ce7c66dab5
|
||||
@@ -44,18 +67,10 @@ automation:
|
||||
|
||||
Verify there are no active leaks before restoring water service.
|
||||
|
||||
- service: script.notify_engine_two_button
|
||||
- service: script.phyn_send_actionable_leak_notification
|
||||
data:
|
||||
title: 'Phyn Leak Detection'
|
||||
value1: 'Phyn is sensing a leak and turned off the water. Please verify.'
|
||||
who: 'parents'
|
||||
group: 'Phyn'
|
||||
action1: 'PHYN_WATER_ON'
|
||||
action2: 'SNOOZE_PHYN_NOTIFICATION'
|
||||
icon1: 'sfsymbols:arrow.up.circle'
|
||||
icon2: 'sfsymbols:clock'
|
||||
level: 'critical'
|
||||
|
||||
source: "initial"
|
||||
|
||||
- service: persistent_notification.create
|
||||
data:
|
||||
title: '🚨 Phyn Leak Detection Alert'
|
||||
@@ -75,12 +90,9 @@ automation:
|
||||
event_data:
|
||||
action: PHYN_WATER_ON
|
||||
action:
|
||||
- service: homeassistant.turn_on
|
||||
entity_id: valve.phyn_shutoff_valve
|
||||
|
||||
- service: persistent_notification.dismiss
|
||||
data:
|
||||
notification_id: 'phyn_leak_detection'
|
||||
- service: valve.open_valve
|
||||
target:
|
||||
entity_id: valve.phyn_shutoff_valve
|
||||
|
||||
- service: script.notify_engine
|
||||
data:
|
||||
@@ -105,17 +117,9 @@ automation:
|
||||
action: SNOOZE_PHYN_NOTIFICATION
|
||||
action:
|
||||
- delay: '00:30:00'
|
||||
- service: script.notify_engine_two_button
|
||||
- service: script.phyn_send_actionable_leak_notification
|
||||
data:
|
||||
title: 'Phyn Leak Detection'
|
||||
value1: 'Phyn is sensing a leak and turned off the water. Please verify.'
|
||||
who: 'parents'
|
||||
group: 'Phyn'
|
||||
action1: 'PHYN_WATER_ON'
|
||||
action2: 'SNOOZE_PHYN_NOTIFICATION'
|
||||
icon1: 'sfsymbols:arrow.up.circle'
|
||||
icon2: 'sfsymbols:clock'
|
||||
level: 'critical'
|
||||
source: "snooze"
|
||||
|
||||
- alias: Dismiss Phyn Notification When Valve Opens
|
||||
id: 3f295bb8-8925-4b22-PHYN-9fe079b295a8
|
||||
|
||||
Reference in New Issue